Configuration of the Line Pack application is made possible on the property pages of the Line Pack EIE device editor in the DDS. To be able to open the Line Pack editor, you must have the CxDdsLPackEditors.dll file registered on your computer (CygNet\Support). See Installing the Line Pack EIE.
Once the driver has been successfully installed, a new Line Pack device can be added to the DDS. The topics that follow describe configuration options.
For on-screen help, hold the mouse over any field or button to view the tooltip.
The following topics discuss how to add and configure a Line Pack device. A Line Pack device instance is defined as an Import/Export device type in the DDS.
Note: If you right-click on an existing import device, that device will be used as a template; right-click in the white space for a blank record.
The Line Pack device editor interface contains seven pages: Device, Settings, Calculations, UDC Map, Global Inputs, Line Pack, and Mass Balance. Each page is described in subsequent topics.
The following table describes the facility and point record configurations required for Line Pack. These must be configured for the facility of every pack sub-segment and for any pack segments that have no pack sub-segments.
| Description | Type | Point Type | Configured on |
|---|---|---|---|
|
Parent facility for Pack Sub-Segments |
Facility Attribute |
N/A |
Facility Service and Settings page |
|
Facility for Pack Segment (for Line Pack and Mass Balance calculations) |
Facility Attribute |
N/A |
Facility Service and Settings page |
|
Pack Sub-Segment Status |
UDC |
Enumeration |
UDC Map page |
|
Pack Sub-Segment Volume |
UDC |
Analog |
UDC Map page |
|
Pack Sub-Segment Length |
UDC |
Analog |
UDC Map page |
|
Pack Sub-Segment Diameter |
UDC |
Analog |
UDC Map page |
More:
Configuring the Line Pack Device
Configuring Calculation Settings